Min.
|
Typ.
|
Max.
|
Unit
|
Remark
|
|
Maximum Rating
|
|
Input Charging Voltage
|
-
|
29.2
|
29.4
|
V
|
|
|
Input Charging Current
|
|
|
6.5
|
A
|
|
|
Output Discharging Voltage
|
20
|
25.6
|
29.2
|
V
|
|
|
Output Discharging Current
|
|
|
60
|
A
|
|
|
Protection Parameters (for Individual Cell)
|
|
Over-Charge Voltage Protection(OVP)
|
3.875
|
3.90
|
3.925
|
V
|
|
|
Over-Charge Voltage Protection Release(OVPR)
|
3.775
|
3.80
|
3.825
|
V
|
|
|
Over-charge detection delay time
|
0.96
|
1.2
|
1.4
|
S
|
|
|
Over-Discharge Voltage Protection (UVP)
|
1.95
|
2.0
|
2.05
|
V
|
|
|
Over-Discharge Voltage Protection Release (UVPR)
|
2.25
|
2.3
|
2.35
|
V
|
|
|
Over-Discharge detection delay time
|
115
|
144
|
173
|
mS
|
|
|
Over-Current Discharge Protection (OCDP)
|
100
|
110
|
120
|
A
|
|
|
Over Temperature Protection
|
|
75
|
|
℃
|
|
|
Short circuit Protection
|
Open Load Release
|
|
|
Cell Balance
|
|
Balance Start Point Voltage
|
3.704
|
3.78
|
3.855
|
V
|
|
|
Balance Close Point Voltage
|
3.528
|
3.6
|
3.672
|
V
|
|
|
Balance current
|
150
|
200
|
250
|
mA
|
|
|
Low current consumption
|
|
Operation
|
|
|
400
|
μA
|
|
|
|
ESD Contact discharge
|
|
±8
|
|
KV
|
|
|
ESD discharge
|
|
±15
|
|
KV
|
|
|
Operating Temperature
|
-10
|
|
60
|
℃
|
|
|
Operating humidity
|
0%
|
|
90%
|
Rh
|
|
|
Storage Temperature
|
-20
|
|
60
|
℃
|
|
|
Storage humidity
|
0%
|
|
90%
|
Rh
|
|